H. Periodic maintenance
IMPORTANT: In winter it is very important to allow the
engine to run for a little while after topping up with distilled
water, otherwise the water can freeze before it has mixed
properly with the battery acid.
WARNING: Be carefully with the battery
solution---danger from corrosion!
H3.7. Check prefilter and fuel fil-
ter (9)
AH19
2
1
3
Drain the prefilter by opening the tap (1) a little in the
bottom of the prefilter. By opening the airscrew (2)inthe
upper part of the prefilter water comes out easier. After
draining water close the tap and the airscrew.
Drain the prefilter more often to reguired.
Drain water from the fuel filter by opening the tap (3)inthe
bottom of the filter. Close the tap.
Drain the fuel filter more often if reguired.
Bleed the fuel system if necessary, (see “Checks and
Adjustments on page 88).
H3.8. Check tyre pressures (10)
NOTE: Check tyre pressures frequently (values are listed
in the Technical Specifications on page 102).
DANGER: Avoid over inflation as excess
pressure may cause the tyre to explode.
It is recommended that the changing of tyres and wheels
is carried out in a professional tyre workshop which is
equiped to handle this type of work.
DANGER: When welding the discs the tyre
must be away from the rim/ disc, DANGER
OF EXPLOSION!
When mounting the tyre on the disc the pressure limit is
250 kPa. If the tyre does not go on the disc properly,
remove it and refit. When the tyre is positioned correctly
on the disc, inflate to correct pressure.